UPS for Mining and Remote Sites in Australia: Rugged Power Protection

Online Centurion UPSs, hardwired 6kVA, battery banks, maintenance bypass and conformal coating: how to protect mine and remote-site equipment with genuine PowerShield.

Short answer: mine sites and remote operations need true online double conversion. Use the Centurion RT in racks and the Centurion tower where there is no rack. PowerShield lists the Centurion tower for remote locations 30+ km from the city grid, for light to heavy industrial environments and for sites with generators. For bigger loads, the hardwired Centurion 6000VA pairs with battery banks and an interlocked maintenance bypass. Conformal coating and three-phase systems are available on project quote.

ARC IP Networks is a trusted PowerShield supplier in Australia: genuine stock at competitive prices, with the full PowerShield Australian warranty, Australia-wide delivery and trade pricing.

Mining power protection at a glance

Your needRecommended PowerShield seriesWhy
Site office, control room and comms racksCenturion RT (PSCERT2000, PSCERT3000)Online double conversion, generator compatible, rack or tower
Field cabinets and demountables (no rack)Centurion tower (PSCE1000, PSCE2000, PSCE3000)Listed for country, industrial and mine/sea environments
Larger hardwired loadsCenturion 6000VA (PSCE6000) or Centurion RT 6000VA Long Run (PSCERT6000L)6000VA / 6000W at unity power factor
Hours, not minutes, of backupBattery banks (PSRTBB12, PSCERBB20)Add banks to extend runtime
Service without shutting downMaintenance bypass (PSMBSW10K, PSMBSR10K)Interlocked bypass for 6 to 10kVA UPSs
Dust and high humidityConformal coating (project quote)Coated boards resist corrosion from conductive dust and condensation
Unattended sitesSNMP card V4 (PSSNMPV4) + relay card (PSAS400T)Remote monitoring and dry-contact alarms

Series and specifications from powershield.com.au product pages.

Based on PowerShield’s PowerShield Mining Solutions page (powershield.com.au), PowerShield product pages and PowerShield partner training. Last reviewed October 2026.

Operator at a remote operations control room with a wall of monitors showing site systems
Remote operations control room, from PowerShield’s mining solutions page (Image: PowerShield)

Why mining needs fit-for-purpose UPS design

PowerShield’s mining guidance is direct: reliable power distribution is essential in metals and mining, and UPS use on site has grown in volume and in rated power. But not every UPS is suitable for connection to a site’s electrical installation. The installation must be designed to be fit for purpose and must meet the site’s design requirements so safety levels are maintained.

That is why PowerShield backs its UPSs with detailed installation manuals and local engineering support in Perth, working with professional installers. Its UPSs are designed by Australian engineers for Australian conditions. PowerShield’s first sizing question is whether a site is metro or regional, because that decides how stable the supply is. And on sites with a generator, the generator takes time to start; without a UPS, equipment still hard-shuts down in that gap.

The 9 power problems on a mine site

PowerShield lists nine power problems: power failure, sag, surge, under voltage, over voltage, spikes, frequency drift, switching transients and harmonic distortion. The Shield System shows which UPS topology fixes which of them:

Protection levelPower problems solvedPowerShield series
Standby (Basic Protection)3 of 9: power failure, power sag, power surgeNinja Slimline (no voltage regulation)
Line-interactive (Enhanced Protection)5 of 9: adds under voltage and over voltage, corrected by AVRSafeGuard, Defender, Commander
True online double conversion (Premium Protection)9 of 9: adds spikes, frequency drift, switching transients and harmonic distortionCenturion tower and rack (three-phase Centurion Pro and Platinum on project quote)

Source: PowerShield Shield System and “9 power problems” (PowerShield partner training).

For mining, PowerShield promotes the Centurion online range, because only online double conversion covers all nine problems. Its tower models add a wide input voltage range, 0.98 input power factor correction and a 50/60 Hz frequency converter mode.

Recommended PowerShield UPS by mining scenario

Site office, control room and comms racks

The Centurion RT is PowerShield’s highest power density single-phase online UPS. It is generator compatible, has programmable outlets and hot-swappable batteries, and fits a 2U rack space or stands as a tower. Choose the PSCERT1000 (900W), PSCERT2000 (1800W) or PSCERT3000 (2700W; needs a 15 A outlet). The lithium Centurion RT LiFePO4 3000VA adds non-flammable cells, three times faster recharge and a 5-year warranty. That suits sites where every battery change means a long drive or a flight.

Field cabinets, crib rooms and demountables

Where there is no rack, the Centurion tower range is the PowerShield choice. Product pages list it for critical power, remote locations 30+ km from the city grid, light to heavy industrial environments, sites with generators and remote connectivity. The PSCE2000 and PSCE3000 are tagged for country, critical, industrial, medical and mine/sea environments. Sizes run from the PSCE1000 (1000VA / 900W, 12.5 kg) to the PSCE3000 (3000VA / 2700W, 28 kg). Battery banks plug in to extend backup time.

Larger loads: 6kVA hardwired

The Centurion 6000VA (PSCE6000) is a hardwired tower rated 6000VA / 6000W with 20 internal batteries. PowerShield offers N+X parallel redundancy on 6K and 10K models. In a rack, the Centurion RT 6000VA Long Run (PSCERT6000L) pairs with the PSCERBB20 battery module (3U, 20 × 12 V 9 Ah, 10-year design life) or the PSRTBB16. The PS6KRN4U bundle packs the PSCERT6000L, PSRTBB16, rails and SNMP card together. Hardwired units must be connected by a professional installer. Under PowerShield’s warranty, hardwired products above 3kVA get on-site repair in Australian capital city metro areas; remote installations may need to go back to a service centre.

Maintenance bypass and distribution

An interlocked bypass keeps loads running while a UPS or its batteries are serviced. The PSMBSW10K is a wall-mount 1:1 bypass for 6kVA or 10kVA UPSs. The PSMBSR10K is a 2U rack bypass. Its mechanical safety microswitch and static bypass activation prevent incorrect switching sequences. Add the PSPDU10K PDU (8 × C13, 4 × C19). For 1kVA to 3kVA Centurion RT and Commander RT units, use the PSMBS2K or PSMBS3K.

Remote monitoring for unattended sites

Every PowerShield UPS includes NetGuard software. The PSSNMPV4 SNMP card adds web access, scheduled shutdowns and Modbus TCP/IP. The PSEMD sensor reports cabinet temperature and humidity. The PSAS400T relay card gives dry-contact alarm outputs on a terminal connector for a PLC or alarm panel.

PowerShield Centurion RT 3000VA true online rack/tower UPS (PSCERT3000)
Centurion RT 3000VA (PSCERT3000): online double conversion, rack or tower (Image: PowerShield)
PowerShield Centurion 3000VA true online tower UPS (PSCE3000)
Centurion 3000VA tower (PSCE3000): listed by PowerShield for mine and sea environments (Image: PowerShield)
PowerShield rack-mount maintenance bypass switch for 6 to 10kVA UPSs (PSMBSR10K)
Rack-mount maintenance bypass switch (PSMBSR10K) for 6 to 10kVA UPSs (Image: PowerShield)

Conformal coating for dust and humidity

Condensation forms on components when humidity is high and the temperature drops fast. That happens when the outside temperature drops suddenly, or simply from cooling fans creating a large temperature difference inside the equipment. On mine sites the dust often has metallic qualities. Moisture plus conductive dust leads to corrosion and short circuits, and electronics fail well before their expected life.

For UPSs exposed to high dust with sustained high humidity, PowerShield offers conformal coating. Every printed circuit board, including the backplane, is coated with a military-specified coating containing corrosion inhibitors. Internal plugs and sockets are protected, and external connectors get a thin film of synthetic grease. PowerShield performs the service to the ASTM B826-03 and ISA 71.04 procedures. It states the coating reduces the corrosion that causes up to 60% of failures in dusty, humid environments. Conformal coating and three-phase Centurion Pro systems are available on project quote.

Worker in a hard hat at industrial electrical switchgear beside the words Power Protection for Mining Applications
PowerShield mining banner: power protection for mining applications (Image: PowerShield)

Genuine PowerShield UPSs for mining and remote sites

Live Australian pricing (inc. GST) and availability are shown on each product page.

Centurion RT 3000VA
Centurion RT 3000VA

Online double conversion, 2700 W, rack or tower, expandable.

View PSCERT3000 →

Centurion RT 2000VA
Centurion RT 2000VA

Online double conversion, 1800 W, takes PSRTBB12.

View PSCERT2000 →

Centurion 3000VA Tower
Centurion 3000VA Tower

Online tower for field cabinets and demountables.

View PSCE3000 →

Centurion 6000VA Tower
Centurion 6000VA Tower

Hardwired, 6000 W, 20 internal batteries.

View PSCE6000 →

Centurion RT 6000VA Long Run
Centurion RT 6000VA Long Run

Rack/tower 6000 W for external battery modules.

View PSCERT6000L →

PSCERBB20 Battery Module
PSCERBB20 Battery Module

3U, 20 batteries, 10-year design life.

View PSCERBB20 →

PSRTBB12 Battery Module
PSRTBB12 Battery Module

Extends PSCERT2000, PSCERT3000 and PSCRT3000.

View PSRTBB12 →

Wall-mount Maintenance Bypass
Wall-mount Maintenance Bypass

Interlocked 1:1 bypass for 6 to 10kVA UPSs.

View PSMBSW10K →

SNMP Comms Card V4
SNMP Comms Card V4

Remote monitoring, shutdown and Modbus TCP/IP.

View PSSNMPV4 →

Sizing and runtime for remote sites

Start with PowerShield’s sizing questions: how stable the power is (metro or regional), the load in watts, rack or tower, the backup time needed and how critical the equipment is. On a generator-backed site, the UPS only needs to carry the load until the generator is stable. On a site with no generator, size for the longest outage you plan to ride through.

Runtime depends on UPS capacity, battery count and load. In PowerShield’s example, a Centurion RT 2000VA at a 1500VA load runs 18 minutes alone, 67 minutes with one battery bank and 101 minutes with two. Centurion battery banks are available with an internal charger for fast recharge, even with large banks. Use our UPS sizing guide and battery bank runtime guide, or send us the load and we will size it.

Why buy PowerShield from ARC IP Networks

ARC IP Networks is a trusted PowerShield supplier in Australia: genuine stock at competitive prices, with the full PowerShield Australian warranty, Australia-wide delivery and trade pricing.

  • Genuine PowerShield stock with the PowerShield Australian warranty, and warranty and RMA questions handled locally by our team.
  • Australia-wide delivery, or free pickup from 6 George Street, Blackburn VIC 3130.
  • Trade accounts for installers, integrators and MSPs, plus project and volume pricing on larger jobs.
  • Pre-sales help on 1300 100 440 (Mon to Fri, 9 to 5 Melbourne time) or info@arcip.com.au.

Supplying a mine site, contractor fleet or several remote sites? Ask for project and trade pricing on UPSs, battery banks, bypass switches and SNMP cards, plus conformal-coated or three-phase options on quote.

See the full PowerShield range at ARC IP Networks.

Get a quote for your mine or remote site

Tell us the load, the site conditions and the runtime you need. We will reply with matched PowerShield models and project or trade pricing. Call 1300 100 440.

Common questions

Straight answers from the ARC IP Networks team. Last reviewed October 2026.

True online double conversion. PowerShield’s Centurion range solves all 9 power problems, is generator compatible, and is listed by PowerShield for remote locations, industrial environments and sites with generators.

Yes. For UPSs exposed to high dust with sustained high humidity, PowerShield offers conformal coating of all circuit boards with a military-specified coating containing corrosion inhibitors. ARC IP Networks supplies it on project quote.

Yes. The Centurion 6000VA (PSCE6000) is a hardwired online UPS rated 6000VA / 6000W. It must be connected by a professional installer to suit the site’s electrical design.

Add PowerShield battery banks matched to the UPS, such as the PSRTBB12 for the Centurion RT 2000VA and 3000VA, or the PSCERBB20 for the Centurion RT 6000VA Long Run. In PowerShield’s example, one battery bank takes a Centurion RT 2000VA from 18 to 67 minutes at a 1500VA load.

Yes, with a maintenance bypass switch. The PSMBSW10K (wall mount) and PSMBSR10K (rack mount) are interlocked bypass switches for 6kVA and 10kVA UPSs. The PSMBS2K and PSMBS3K suit 1kVA to 3kVA Centurion RT and Commander RT units.

PowerShield provides detailed installation manuals and local engineering support in Perth to work with professional installers. ARC IP Networks handles orders, warranty and RMA questions for the genuine PowerShield units we supply.

Yes. Three-phase Centurion Pro and Platinum systems are available from ARC IP Networks on project quote. Call 1300 100 440 with your load and site details.

UPS for ICT in Australia: Server Rooms, Comms Racks and Networks
Which PowerShield UPS to use for comms cabinets, network racks, servers and VMware hosts: shallow-depth Defender, pure sine Commander RT and online Centurion RT, with SNMP shutdown.