Skip to Content
Ubiquiti UniFi UACC-Retrofit-PSU-12V — 12V DC / 5A (80W) Power Supply with Optional SLA Backup Battery Support for the UniFi Retrofit Hub (UA-Hub-Retrofit)

Price:

129.00


Ubiquiti UniFi Enterprise NVR Core (ENVR-Core) — 3U Rack-Mount 16-Bay Network Video Recorder for 500 HD / 300 4K Cameras with 128-Core ARM, 64 GB RAM, 2× 25G SFP28, Dual SFF-8644 Drive Expansion (Up to 48 Drives) and Hot-Swap Dual PSU
Ubiquiti UniFi Enterprise NVR Core (ENVR-Core) — 3U Rack-Mount 16-Bay Network Video Recorder for 500 HD / 300 4K Cameras with 128-Core ARM, 64 GB RAM, 2× 25G SFP28, Dual SFF-8644 Drive Expansion (Up to 48 Drives) and Hot-Swap Dual PSU
11,500.01
11,500.01
Ubiquiti UniFi UA-Retrofit-Hub-2 — UniFi Access 2-Door Retrofit Hub with Wiegand / OSDP Reader Support, 12/24V DC Lock Outputs, DIN Rail Mount (10,000 Users)
Ubiquiti UniFi UA-Retrofit-Hub-2 — UniFi Access 2-Door Retrofit Hub with Wiegand / OSDP Reader Support, 12/24V DC Lock Outputs, DIN Rail Mount (10,000 Users)
419.00
419.00

Ubiquiti UniFi UACC-Retrofit-PSU-12V — 12V DC / 5A (80W) Power Supply with Optional SLA Backup Battery Support for the UniFi Retrofit Hub (UA-Hub-Retrofit)

https://arcip.com.au/web/image/product.template/9731/image_1920?unique=4829406
UACC-Retrofit-PSU-12V is the dedicated power supply for the UniFi Access Retrofit Hub — a compact 100–240V AC to 12V DC (5A / 80W) adapter that also drives a 12V SLA backup battery (0.5A charge current) for stay-online operation during mains failure. 85% efficient, three status LEDs, -10 to 40 °C operating range. Australian stock from ARC IP Networks.

129.00 129.0 AUD 129.00 incl. GST

Not Available For Sale


  • Form Factor
  • Compatibility
  • Output Rating
  • Input Voltage
  • Battery Backup
  • Efficiency
  • Wiring Connection
  • LEDs

This combination does not exist.

Indoor UniFi Ubiquiti Door Access UniFi Access Accessories Power Supply PSU 12V 5A 80W SLA Battery Backup Retrofit Hub
  • Stock

    Authorised Australian Reseller | Australian Stock | Genuine Local Warranty

  • Instalment
    Buy Now, Pay Later 
  • [Warranty Information] Warranty
    Manufacturer Warranty 
Estimate delivery
Shipping calculated at checkout
Estimate delivery times: 3-7 business days 
Guaranteed Safe Checkout
Guaranteed Safe Checkout
SKU
UACC-Retrofit-PSU-12V
Barcode
810177163930
Tags
UACC-Retrofit-PSU-12V
Ubiquiti UniFi UACC-Retrofit-PSU-12V — 12V DC / 5A (80W) Power Supply with Optional SLA Backup Battery Support for the UniFi Retrofit Hub (UA-Hub-Retrofit)
💼

Deal Registration Required

The Ubiquiti Retrofit PSU 12V (UACC-Retrofit-PSU-12V) ships under Ubiquiti’s deal-registration program for project pricing and deployment support. Please contact ARC IP Networks before ordering to register the deal, confirm lead time, and unlock project pricing.

UACC-Retrofit-PSU-12V Front

UACC-Retrofit-PSU-12V Wiring + Battery Connection

Features

  • Dedicated power supply for the UniFi Access Retrofit Hub (UA-Hub-Retrofit) — sized to drive the hub plus its connected door hardware.
  • Universal AC input (100–240V AC, 50/60 Hz) — installs anywhere in the world without re-tooling.
  • 12V DC output rated at 5A (80W maximum) — meets the Retrofit Hub's power envelope with margin for connected strike or maglock loads.
  • Optional 12V SLA (sealed lead-acid) backup battery support with built-in 0.5A charging current — keeps door access online during mains failure.
  • Three independent wiring connections: (1) AC mains input, (1) DC output to the Retrofit Hub, and (1) DC input/output for the SLA battery.
  • 85% rated efficiency — runs cool, low ambient heat impact when wall-mounted in an electrical cupboard.
  • (3) status LEDs surface AC presence, DC output and battery state at a glance.
  • Compact 127 × 76 × 35 mm aluminium housing, 350 g — fits easily in a typical access-control wall enclosure.
  • Wide operating range -10 to 40 °C ambient (storage -40 to 70 °C), 10–90% non-condensing humidity.
  • CE, FCC and IC certified.
  • Designed exclusively for the UniFi Access Retrofit Hub — do not use as a generic 12V wall adapter.

Specifications

Mechanical
Dimensions127 × 76 × 35 mm
Weight350 g
Hardware
Power Method100–240V AC, 50/60 Hz; 12V SLA battery
SLA Backup Battery12V; 0.5A charging current
Wiring Connection(1) AC input; (1) DC output (to Retrofit Hub); (1) DC input/output (to battery)
Max. Power Consumption80W
Efficiency85%
Output Rating12V DC, 5A
LEDs(3) Status
Ambient Operating Temperature-10 to 40 °C
Ambient Storage Temperature-40 to 70 °C
Ambient Operating Humidity10 to 90% non-condensing
CertificationsCE, FCC, IC
Compatibility
Host DeviceUniFi Access Retrofit Hub (UA-Hub-Retrofit)

Professional Overview

The UACC-Retrofit-PSU-12V is the dedicated power supply for the UniFi Access Retrofit Hub (UA-Hub-Retrofit). The Retrofit Hub is designed to drop into an existing third-party access control wall enclosure and convert it into a UniFi Access door — but it needs a clean 12V DC source rated for both the hub itself and the door hardware (electric strike, maglock, request-to-exit, REX sensor) it drives. That is the gap this PSU fills.

Electrically, the PSU is a 100–240V AC universal-input adapter delivering 12V DC at 5A (80W maximum), with 85% rated efficiency. Three independent wiring terminals provide a clean separation between AC mains input, the DC output that feeds the Retrofit Hub, and a third bidirectional DC connection sized to charge and discharge an optional 12V SLA (sealed lead-acid) backup battery at 0.5A charge current. Adding a battery turns the door into a stay-online endpoint during mains failure — important for after-hours access at sites where the door is the only ingress.

Three front-mounted LEDs report on AC mains presence, DC output health and battery state respectively — at-a-glance diagnostics from outside the enclosure, useful during site commissioning and during fault investigation. The housing is a compact 127 × 76 × 35 mm aluminium block weighing 350 g, designed to sit alongside the Retrofit Hub inside a standard access-control wall box without dominating the available volume.

Environmentally, the PSU is rated for -10 to 40 °C operating range and -40 to 70 °C storage, with 10–90% non-condensing humidity — suitable for unconditioned plant rooms, garage controllers and outdoor weather-rated enclosures. Certifications cover CE, FCC and IC. The PSU is purpose-engineered for the UniFi Access Retrofit Hub and should not be substituted for a generic 12V wall adapter, since the battery-management circuitry and three-wire terminal layout are part of the Retrofit Hub installation pattern. Australian stock from ARC IP Networks.

Form Factor Indoor wall PSU
Compatibility UniFi Access Retrofit Hub (UA-Hub-Retrofit)
Output Rating 12V DC, 5A (80W max)
Input Voltage 100–240V AC, 50/60 Hz
Battery Backup 12V SLA, 0.5A charge current
Efficiency 85%
Wiring Connection (1) AC input + (1) DC output + (1) DC battery
LEDs (3) Status — AC / DC / Battery

Accurate Shipping Costs

Our online shipping calculator is designed to provide a final, accurate shipping cost based on the items in your cart and your delivery postcode. Shipping costs are calculated at checkout based on your order and delivery postcode. The final cost is calculated based on several factors which are automatically accounted for by our system, including:

  • The stock location of the item(s) across our warehouses.
  • Orders with multiple items that may require special packaging.
  • The weight and dimensions of the order (including heavy or oversized items).
  • The delivery courier servicing your specific region.

Delivery Times


 

Standard Processing


Most orders placed by 2pm AEDT are dispatched for next working day delivery. Larger orders may require 1-2 additional business days for processing. If timing is critical, please contact us to discuss expedited options (additional charges may apply).


Delivery Timeframes


Region

Processing Time

Express Delivery

Standard Delivery

VIC, NSW, SA, QLD Metro, TAS

1-2 business days

1-2 business days

2-4 business days

NT, WA, QLD Rural

1-2 business days

1-2 business days

3-5 business days

New Zealand

1-2 business days

2-3 business days

4-10 business days

Please note: Processing times may extend during peak periods such as Christmas and end of financial year.

Free Warehouse Pickup



Save on shipping costs with free pickup from our ARC IP Networks Blackburn warehouse. Simply place your order online or by phone, and collect during business hours (Monday to Friday). Please allow time for picking and packing. For urgent orders, call 1300 100 440 to confirm your order is ready.

ARC IP Networks Pickup Address: 6 George Street, Blackburn, VIC 3130


Insurance & Tracking



All ARC IP Networks shipments are fully insured and trackable. Once dispatched, you'll receive an email with your tracking number and courier website details. If your item is confirmed lost or damaged by our courier, we'll arrange a replacement in consultation with you.


International Shipping



ARC IP Networks ships to New Zealand. Please note:


  • Import duties and taxes vary by country
  • Buyers are responsible for all customs charges
  • Contact your local customs authority before ordering
  • We'll provide required documentation for smooth customs clearance
  • Buyers cover all shipping costs for returns due to refused duties/taxes


Delivery Requirements


Signature Required


All deliveries must be signed for. If you won't be home, contact our Sales Support team to arrange Authority to Leave. Important: Authority to Leave voids shipping insurance if parcels are lost or stolen.


Delivery Restrictions


We do not deliver to PO Boxes or Parcel Lockers as our couriers cannot access them. Orders sent to these addresses will be returned, incurring redelivery fees.


Shipping Issue Resolution


ARC IP Networks works closely with our shipping partners to resolve any delivery issues quickly and fairly:


  1. Confirmation: We verify expected delivery dates with our shipping partners
  2. Investigation: Issues outside normal timeframes trigger formal investigations
  3. Communication: We keep you updated throughout the resolution process
  4. Resolution: Confirmed lost items are replaced or refunded after investigation completion


Please note: Refunds for lost, missing, or delayed orders cannot be processed until shipping partner investigations are complete. This does not affect your rights under the Australian Consumer Law, and refunds or replacements will be provided where required once loss or damage is confirmed.

Warranty & Faulty Products

ARC IP Networks complies with the Australian Consumer Law (ACL).

If a product is faulty, damaged, not of acceptable quality, or does not perform as advertised, you are entitled to a repair, replacement, or refund in accordance with ACL.

Manufacturer Warranty Returns

For faults developing after 14 days within the warranty period:

  • Contact ARC IP Networks first at info@arcip.com.au or 1300 100 440
  • We will assess the issue and coordinate with manufacturers, authorised service centres, or distributors on your behalf
  • Where required, a manufacturer RMA may be arranged
  • ARC IP Networks manages the return process and next steps

Dead on Arrival (DOA)

Products that arrive faulty or damaged must be reported within 14 days of delivery.

ARC IP Networks will arrange assessment, replacement, or refund as appropriate.

Change of Mind & Non-Faulty Returns

Change-of-mind returns must be requested within 14 days of delivery. For change-of-mind returns, the product must be unused, unopened, in its original packaging, and returned with all accessories and documentation. These conditions apply only to change-of-mind returns and do not limit or exclude your rights under the Australian Consumer Law. Some products are not eligible for change-of-mind returns, including:

  • Ex-demo products
  • Clearance or markdown items
  • Special-order items
  • Products clearly marked “No Change-of-Mind Returns”

Important

This does not affect your rights under Australian Consumer Law.

If a product is faulty, not of acceptable quality, or does not meet advertised specifications, it remains eligible for return regardless of category.

Refunds & Processing Timeframes

  • Approved refunds are processed within 7 business days of receiving returned goods
  • Refunds are issued to the original payment method, unless otherwise agreed
  • Replacement or repair may be offered where appropriate
  • Store credit may be offered only with customer consent

Handling fees and non-returnable service charges may not be refundable where permitted by law.


Restocking Fees

For approved change-of-mind or non-faulty returns, a 15% restocking fee applies.

  • Any applicable restocking fee will be clearly communicated prior to return approval
  • The fee will be deducted from the refund amount
  • Restocking fees do not apply to returns made under the Australian Consumer Law, including faulty, damaged, or misrepresented goods.

Return Shipping Costs

  • Change-of-mind returns: The customer is responsible for return shipping costs.
  • Faulty or defective products: ARC IP Networks covers return shipping under Australian Consumer Law.

Non-Warranty Repairs

For issues not covered by warranty:

  • ARC IP Networks will provide a quote before proceeding
  • Customers are responsible for all shipping and service costs
  • No repairs are undertaken without customer approval

Return Methods

Returns may be made:

  • In-store at ARC IP Networks – 6 George Street, Blackburn VIC 3130
  • Or by shipment as instructed by our support team

Proof of purchase is required for all returns.

Enquire About this Product


Any questions about this product? Fill out the form below, and we'll get back to you soon!

Accessory Products