Ubiquiti UA-G2-SK-PRO specifications
Overview
| In the Box | (1) Door Hub / (1) G2 Reader Pro / (1) G2 Reader / (2) Pocket Keyfobs |
|---|
Door Hub
| Dimensions | 174.9 x 126 x 32.9 mm / (6.9 x 5 x 1.3") |
|---|
| Supported Doors | 1 |
|---|
| Maximum User Count | 6,000 |
|---|
| Input Terminals | (2) Door exit request / (1) Door position / (1) Emergency |
|---|
| Power Method | PoE++ / UL 294 Power-limited Class 2 PSU / UL 60950-1/62368-1 LPS/PS2 PSU |
|---|
| Weight | 363 g (12.8 oz) |
|---|
| Enclosure Material | Polycarbonate |
|---|
| Mount Material | Polycarbonate |
|---|
| Mounting | DIN-rail (Included) |
|---|
| Networking Interface | (5) 10/100/1000 Base-T |
|---|
| PoE Interface | (1) PoE++ input, 50V DC, 1A / (4) PoE outputs, 50V DC, 30W per port / (Max 45W aggregated) |
|---|
| Max. Power Consumption | 30W (Without PoE output) / 50W (With PoE output) |
|---|
| Digital Input | Request to exit, request to enter, remote release, door position sensor |
|---|
| Dry Output Relay | Lock: 30V DC, 1A / Aux: 30V DC, 1A |
|---|
| Powered Output Relay | Lock: 12V DC, 1A / Aux: 12V DC, 0.33A / 12V DC, 0.33A |
|---|
| LEDs | B/W Learn More |
|---|
| Button | (1) Factory reset |
|---|
| UA-Lock-Electric
(400mA) | 24 AWG length: 25 m (82 ft) / 22 AWG length: 42 m (138 ft) / 20 AWG length: 66 m (217 ft) / 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft) |
|---|
| UA-Lock-Magnetic-540kg (500mA) | 24 AWG length: 20 m (66 ft) / 22 AWG length: 32 m (105 ft) / 20 AWG length: 51 m (167 ft) / 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft) |
|---|
| UA-Lock-Magnetic-270kg (800mA) | 24 AWG length: 12 m (39 ft) / 22 AWG length: 20 m (66 ft) / 20 AWG length: 30 m (98 ft) / 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft) |
|---|
| Other locks
(1A) | 24 AWG length: 9 m (30 ft) / 22 AWG length: 15 m (49 ft) / 20 AWG length: 24 m (79 ft) / 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft) |
|---|
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. / The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable. |
|---|
| UL 294 Level | Destructive attack: Level I / Line security: Level I / Endurance: Level I / Standby power: Level I |
|---|
| UL 294 Statement | Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. / The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |
|---|
| CAN/ULC-60839-11-1 Grade | Grade assignment: 1 |
|---|
| Ambient Operating Temperature | 0 to 40° C (32 to 104° F) |
|---|
| Ambient Operating Humidity | 5 to 95% noncondensing |
|---|
| Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 |
|---|
| Management Application | UniFi Access |
|---|
| Software Information | The software version can be checked at https://unifi.ui.com |
|---|
| Document number, and issue date and/or revision level | UA-Hub-Door002, V01 |
|---|
G2 Reader
| Dimensions | 93 x 40 x 36.5 mm / (3.7 x 1.6 x 1.4") |
|---|
| Weatherproofing | IP55 |
|---|
| Weight | 82 g (2.9 oz) |
|---|
| Enclosure Material | Polycarbonate, glass |
|---|
| Mount Material | Aluminium alloy |
|---|
| Mounting | In-wall, gang box (Included) / Junction box (Optional) |
|---|
| Networking Interface | (1) 10/100 MbE RJ45 port |
|---|
| Connectivity | BLE 4.1 / NFC |
|---|
| Power Method | PoE / UL 294 Power-limited Class 2 PSU / UL 60950-1/62368-1 LPS/PS2 PSU |
|---|
| Max. Power Consumption | 5W |
|---|
| Supported Voltage Range | 48V DC |
|---|
| ESD/EMP Protection | Air: ± 15kV, contact: ± 8kV |
|---|
| Sensors | Proximity sensor |
|---|
| Speaker | (1) Yes, 0.7W |
|---|
| LEDs | R/G/B/W Learn More |
|---|
| Button | (1) Factory reset |
|---|
| NFC Read Range | < 30 mm (1.18'') |
|---|
| NFC Frequency | 13.56 MHz |
|---|
| NFC Technology | ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) / MIFARE Classic / MIFARE DESFIRE / Sony FeliCa™ (ID only) / NFC Forum tags T1T, T2T, T3T, T4T and T5T |
|---|
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. / The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable. |
|---|
| UL 294 Level | Destructive attack: Level I / Line security: Level I / Endurance: Level I / Standby power: Level I |
|---|
| UL 294 Statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. / The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |
|---|
| CAN/ULC-60839-11-1 Grade | Grade assignment: I |
|---|
| Ambient Operating Temperature | -30 to 45° C (-22 to 113° F) |
|---|
| Ambient Operating Humidity | 5 to 90% noncondensing |
|---|
| Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 |
|---|
| Document number, and issue date and/or revision level | UA-G2/UA-G2-Black, V02 |
|---|
| Management Application | UniFi Access |
|---|
| Software Information | The software version can be checked at https://unifi.ui.com |
|---|
Pocket Keyfob
| Dimensions | 84 x 39 x 7.4 mm / (3.3 x 1.5 x 0.29") |
|---|
| Weight | 16 g (0.56 oz) |
|---|
| Enclosure Material | Polycarbonate, stainless steel, silicone rubber |
|---|
| Weatherproofing | IP54 |
|---|
| Ambient Operating Humidity | 10 to 90% noncondensing |
|---|
| Ambient Operating Temperature | -10 to 45° C (14 to 113° F) |
|---|
| NFC Frequency | 13.56 MHz |
|---|
| NFC Technology | ISO/IEC 14443 Type A / MIFARE DESFire EV3 4K / UniFi Access Proprietary Security Protocol |
|---|
| Certification | CE |
|---|
Specifications from Ubiquiti's official product data for the UA-G2-SK-Pro, checked October 2026.
The UniFi Access G2 Starter Kit Pro in depth
Complete entry and exit control for one door
The UA-G2-SK-PRO bundles everything the record lists for managing a single door with two readers: one Door Hub, one G2 Reader Pro, one G2 Reader and two Pocket Keyfobs. The second reader can be used for door exit, or for entry on an additional door, although a second Hub is required for that additional door. The kit is managed through the UniFi Access application.
Door Hub
The Door Hub supports 1 door and a maximum of 6,000 users. It has (5) 10/100/1000 Base-T ports, a PoE++ input (50V DC, 1A) and (4) PoE outputs at 50V DC, 30W per port, with a maximum of 45W aggregated. Inputs cover door exit request, door position and emergency. Lock and auxiliary relays are provided as dry or powered outputs. The polycarbonate enclosure measures 174.9 x 126 x 32.9 mm, weighs 363 g and includes DIN-rail mounting.
G2 Reader Pro, G2 Reader and Pocket Keyfobs
The G2 Reader Pro has a 120 mm (4.7") portrait capacitive touch display, a proximity sensor, a 1.5W speaker, BLE 4.2 and NFC. The G2 Reader is a compact unit with BLE 4.1, NFC and a 0.7W speaker. Both readers are IP55-rated, use PoE, and have an NFC read range under 30 mm. The two Pocket Keyfobs are IP54-rated and support MIFARE DESFire EV3 4K.